Next Page Previous Page Handbook Home Tools & Aids Search Handbook
5. Process Improvement
5.5. Advanced topics

5.5.8.

What are small composite designs?

Small composite designs save runs compared to Resolution V response surface designs by adding star points to a Resolution III design
 
 
 
 
 
 
 
 
 
 
 
 

Design for 4 factors
 

Response surface designs (RSD) were described earlier. A typical RSD requires about 13 runs for 2 factors, 20 runs for 3 factors, 31 runs for 4 factors, and 32 runs for 5 factors.  It is obvious that, once you have four or more factors you wish to include in a RSD, you will need more than one lot of experimental units for your basic design.  This is what most statistical software today will give you, including RS/1, JMP, and SAS.  However, there is a way to cut down on the number of runs, as suggested by H.O Hartley  in his paper 'Smallest Composite Designs for Quadratic Response Surfaces'  published in Biometrics, December 1959 

This method addresses the theory that using a Resolution V design as the smallest fractional design to create an RSD is unnecessary.  This method adds star points to designs of Resolution III, and then uses the star points toclear the main effects of aliasing with the two-factor interactions.  This method will not estimate three-factor interactions or higher. It provides poor interaction coefficient estimates, and should not be used unless the error variability is negligible compared to the systematic effects of the factors.

This could be particularly useful when you have a design containing four or five factors and you wish to only use the experimental units from one lot. 

The following is a design for four factors.  You would want to randomize these runs before implementing them.  -1 and +1 represent the low and high settings of each factor. 

TABLE 5.11  Four factors:  Factorial design section is based on a generator of I = X1*X2*X3, Resolution III.  -a and +a are the star points, calculated beyond the factorial range.  0 represents the midpoint of the factor range

Determining a in Central Composite Designs

To maintain rotatability for usual CCD's, the value of a was determined by the number of treatment combinations in the factorial portion of the central composite design: 

However, small composite designs are not rotatable, regardless of the choice of a. For small composite designs, a should not be smaller than [number of factorial runs]1/4 nor larger than k1/2.
Handbook Home Tools & Aids Search Handbook Previous Page Next Page